Background context:
Modernization of 3D printing has allowed for the production of porous titanium interbody cages (3D-pTi) which purportedly optimize implant characteristics and increase osseointegration; however, this remains largely unstudied in vivo.
Purpose:
To compare osseointegration of three-dimensional (3D) titanium cages without bone graft and Polyether-ether-ketone (PEEK) interbody cages with autologous iliac crest bone graft (AICBG).
Study design:
Animal study utilizing an ovine in vivo model of lumbar fusion.
Methods:
Interbody cages of PEEK or 3D-pTi supplied by Spineart SA (Geneva, Switzerland) were implanted in 7 living sheep at L2-L3 and L4-L5, leaving the intervening disk space untreated. Both implant materials were used in each sheep and randomized to the aforementioned disk spaces. Computed tomography (CT) was obtained at 4 weeks and 8 weeks. MicroCT and histological sections were obtained to evaluate osseointegration.
Results:
MicroCT demonstrated osseous in-growth of native cancellous bone in the trabecular architecture of the 3D-pTi interbody cages and no interaction between the PEEK cages with the surrounding native bone. Qualitative histology revealed robust osseointegration in 3D-pTi implants and negligible osseointegration with localized fibrosis in PEEK implants. Evidence of intramembranous and endochondral ossification was apparent with the 3D-pTi cages. Quantitative histometric bone implant contact demonstrated significantly more contact in the 3D-pTi implants vs. PEEK (p<0.001); region of interest calculations also demonstrated significantly greater osseous and cartilaginous interdigitation at the implant-native bone interface with the 3D-pTi cages (p=0.008 and p=0.015, respectively).
Conclusion:
3D-pTi interbody cages without bone graft outperform PEEK interbody cages with AICBG in terms of osseointegration at 4 and 8 weeks post-operatively in an ovine lumbar fusion model.
Clinical significance:
3D-pTi interbody cages demonstrated early and robust osseointegration without any bone graft or additive osteoinductive agents. This may yield early stability in anterior lumbar arthrodesis and potentially bolster the rate of successful fusion. This could be of particular advantage in patients with spinal neoplasms needing post-ablative arthrodesis, where local autograft use would be ill advised.
Keywords:
additive manufacturing; interbody cages; interbody fusion; three-dimensional printing; titanium.