. 2021 May 17;e3498.
doi: 10.1002/cnm.3498.
Online ahead of print.
Affiliations
Affiliations
- 1 Department of Mechanical Engineering, Tsinghua University, Beijing, China.
- 2 Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen, China.
- 3 Spine Pain Begone Clinic, San Antonio, Texas, USA.
Item in Clipboard
Hangkai Shen et al.
Int J Numer Method Biomed Eng.
.
Display options
Format
. 2021 May 17;e3498.
doi: 10.1002/cnm.3498.
Online ahead of print.
Affiliations
- 1 Department of Mechanical Engineering, Tsinghua University, Beijing, China.
- 2 Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen, China.
- 3 Spine Pain Begone Clinic, San Antonio, Texas, USA.
Item in Clipboard
Display options
Format
Abstract
Lumbar spinal fusion may cause adjacent segment degeneration (ASD) in the long term. Recently, inserting an interspinous process device (IPD) proximal to the fusion has been proposed to prevent ASD. The aim of this study was to investigate the biomechanics of lumbar fusion with proximal IPD implantation (LFPI) under both static loads and whole body vibration (WBV). A previously validated finite element (FE) model of the L1-5 lumbar spine was modified to simulate L4-5 fusion. Three different IPDs (Coflex-F, Wallis and DIAM) were inserted at the L3-4 segment of the fusion model to construct the LFPI models. The intact and surgical FE models were analyzed under static loads and WBV, respectively. Under static loading conditions, LFPI decreased range of motion (ROM) and intradiscal pressure (IDP) at the transition segment L3-4 compared with the fusion case. At the segment (L2-3) adjacent to the transition level, LFPI induced higher motion and IDP than rigid fusion. Under WBV, vibration amplitudes of the L3-4 IDP and L4-5 facet joint force (FJF) decreased by more than 54.3% after surgery. The LFPI model with the DIAM system offered the most comparable biomechanics to the intact model under static loads, and decreased the dynamic responses of the L4-5 FJF under WBV. The LFPI model with the Wallis and Coflex-F systems could stabilize the transition segment, and decrease dynamic responses of the L3-4 IDP. The DIAM system may be more suitable in LFPI. This article is protected by copyright. All rights reserved.
Keywords:
Adjacent segment degeneration; Finite element; Interspinous process device; Intradiscal pressure; Lumbar spine; Whole body vibration.
This article is protected by copyright. All rights reserved.
Similar articles
-
Biomechanical Analysis of Different Lumbar Interspinous Process Devices: A Finite Element Study.
Shen H, Fogel GR, Zhu J, Liao Z, Liu W.
Shen H, et al.
World Neurosurg. 2019 Jul;127:e1112-e1119. doi: 10.1016/j.wneu.2019.04.051. Epub 2019 Apr 10.
World Neurosurg. 2019.PMID: 30980982
-
Biomechanical effects of hybrid stabilization on the risk of proximal adjacent-segment degeneration following lumbar spinal fusion using an interspinous device or a pedicle screw-based dynamic fixator.
Lee CH, Kim YE, Lee HJ, Kim DG, Kim CH.
Lee CH, et al.
J Neurosurg Spine. 2017 Dec;27(6):643-649. doi: 10.3171/2017.3.SPINE161169. Epub 2017 Sep 22.
J Neurosurg Spine. 2017.PMID: 28937328
-
Does oblique lumbar interbody fusion promote adjacent degeneration in degenerative disc disease: A finite element analysis.
Du CF, Cai XY, Gui W, Sun MS, Liu ZX, Liu CJ, Zhang CQ, Huang YP.
Du CF, et al.
Comput Biol Med. 2021 Jan;128:104122. doi: 10.1016/j.compbiomed.2020.104122. Epub 2020 Nov 21.
Comput Biol Med. 2021.PMID: 33248365
-
Biomechanical analysis of a newly developed interspinous process device conjunction with interbody cage based on a finite element model.
Bae IS, Bak KH, Chun HJ, Ryu JI, Park SJ, Lee SJ.
Bae IS, et al.
PLoS One. 2020 Dec 11;15(12):e0243771. doi: 10.1371/journal.pone.0243771. eCollection 2020.
PLoS One. 2020.PMID: 33306706
Free PMC article. -
Reduction in adjacent-segment degeneration after multilevel posterior lumbar interbody fusion with proximal DIAM implantation.
Lu K, Liliang PC, Wang HK, Liang CL, Chen JS, Chen TB, Wang KW, Chen HJ.
Lu K, et al.
J Neurosurg Spine. 2015 Aug;23(2):190-6. doi: 10.3171/2014.12.SPINE14666. Epub 2015 May 1.
J Neurosurg Spine. 2015.PMID: 25932598
Cite