. 2021 Aug 25;13(8):e17431.
doi: 10.7759/cureus.17431.
eCollection 2021 Aug.
Affiliations
Affiliations
- 1 Department of Surgery, King Abdulaziz University Hospital, Jeddah, SAU.
- 2 Department of Surgery, Faculty of Medicine, King Abdulaziz University, Jeddah, SAU.
- 3 Division of Neurosurgery, Department of Surgery, Faculty of Medicine, King Abdulaziz University, Jeddah, SAU.
Item in Clipboard
Ashwaq Alqurashi et al.
Cureus.
.
Display options
Format
. 2021 Aug 25;13(8):e17431.
doi: 10.7759/cureus.17431.
eCollection 2021 Aug.
Affiliations
- 1 Department of Surgery, King Abdulaziz University Hospital, Jeddah, SAU.
- 2 Department of Surgery, Faculty of Medicine, King Abdulaziz University, Jeddah, SAU.
- 3 Division of Neurosurgery, Department of Surgery, Faculty of Medicine, King Abdulaziz University, Jeddah, SAU.
Item in Clipboard
Display options
Format
Abstract
Background Transpedicular screws are a common adjunct for lumbar spine fusion. Accurate screw placement to prevent neurological injury has been the subject of many studies. The adoption of spine neuronavigation has shown a significant decrease in screw malposition morbidity. We aim to evaluate the accuracy of pedicle screw insertion using intraoperative CT-guided navigation in lumbar spondylosis. Methods We reviewed a prospective registry-based cohort study. This included patients who underwent transpedicular screws insertion for lumbar spondylosis under intraoperative CT-guided navigation (iCT-Nav) and compared it to another group operated using conventional fluoroscopy (FS) over one year. In addition, the correlation between clinical outcome using the visual analog scale (VAS) and short 12 physical component scores (SF-12 PCS) and hospital stay was reported. Results Fifteen patients were included in the iCT-Nav group compared to 42 patients in the FS group. The median age of the iCT-Nav group was 59.3 years old (27-76 years) versus 45 years old (20-60 years) in the FS group. The number of screws was 98 in the iCT-Nav group and 252 screws in the FS group. Based on more than 2-mm breach increments measured on CT images, lumbar pedicular screw placement accuracy was 100% in the iCT-Nav group and 86.9% in the FS group. None of the patients in the iCT-Nav group had to undergo any postoperative revisions. On the other hand, two patients of the FS group developed new postoperative symptoms related to displaced screws and required readmission and revision surgery. Conclusion In a commonly performed pedicular fixation in lumbar spondylosis, iCT-Nav has been shown to improve the accuracy of pedicle screw placement, hospital stay, and functional outcomes compared to FS.
Keywords:
conventional fluoroscopy; intraoperative ct; navigation; pedicle screws accuracy; spine.
Copyright © 2021, Alqurashi et al.
Conflict of interest statement
The authors have declared that no competing interests exist.
Figures
References
-
-
Internal fixation for lumbosacral fusion. King D. https://pubmed.ncbi.nlm.nih.gov/18109577/ J Bone Joint Surg Am. 1948;30A:560–565.
–
PubMed
-
-
-
Accuracy of pedicle screw placement in lumbar vertebrae. Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Spine (Phila Pa 1976) 1996;21:1320–1324.
–
PubMed
-
-
-
Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Parker SL, McGirt MJ, Farber SH, et al. Neurosurgery. 2011;68:170–178.
–
PubMed
-
-
-
Accuracy of pedicular screw placement in vivo. Gertzbein SD, Robbins SE. Spine (Phila Pa 1976) 1990;15:11–14.
–
PubMed
-
Cite