Background:
Despite the wide use of intraoperative neurophysiological monitoring (IONM) in spinal surgeries, the efficacy of IONM during percutaneous endoscopic transforaminal lumbar interbody fusion (PE-TLIF) surgery in detecting postoperative neurological deficits has not been well characterized.
Methods:
MIONM data from 113 consecutive patients who underwent PE-TLIF surgeries between June 2018 and April 2020 were retrospectively reviewed. Postoperative neurological deficits were documented and analyzed, and the efficacy and specificity of various IONM techniques were compared.
Results:
Of the 113 consecutive patients, 12 (10.6%) with IONM alerts were identified. The MIONM sensitivity and specificity were 100 and 96.2%, respectively. The frequency of neurological complications, including minor deficits, was 6.2% (n = 7); all of the neurological complications were temporary. The ability of single IONM modalities to detect neurological complications varied between 25.0 and 66.6%, whereas that of all modalities was 100%.
Conclusions:
MIONM is more effective and accurate than unimodal monitoring in assessing nerve root function during PE-TLIF surgeries, reducing both neurological complications and false-negative findings. We recommend MIONM in PE-TLIF surgeries.
Keywords:
Electromyography; Motor-evoked potentials; Multimodal intraoperative neurophysiological monitoring; Percutaneous endoscopic transforaminal lumbar interbody fusion; Somatosensory-evoked potentials.