. 2023 Apr 10;18(4):e0282737.
doi: 10.1371/journal.pone.0282737.
eCollection 2023.
Affiliations
Affiliations
- 1 Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan.
- 2 Department of Medical Imaging and Radiological Technology, Yuanpei University of Medical Technology, Hsinchu, Taiwan.
- 3 Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan.
- 4 Graduate Institute of Biomedical Sciences, China Medical University, Taichung, Taiwan.
- 5 x-Dimension Center for Medical Research and Translation, China Medical University Hospital, Taichung, Taiwan.
- 6 3D Printing Medical Research Institute, Asia University, Taichung, Taiwan.
- 7 Department of Neurosurgery, China Medical University Hsinchu Hospital, Hsinchu, Taiwan.
Free PMC article
Item in Clipboard
Yun-Xuan Tang et al.
PLoS One.
.
Free PMC article
Display options
Format
. 2023 Apr 10;18(4):e0282737.
doi: 10.1371/journal.pone.0282737.
eCollection 2023.
Affiliations
- 1 Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan.
- 2 Department of Medical Imaging and Radiological Technology, Yuanpei University of Medical Technology, Hsinchu, Taiwan.
- 3 Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan.
- 4 Graduate Institute of Biomedical Sciences, China Medical University, Taichung, Taiwan.
- 5 x-Dimension Center for Medical Research and Translation, China Medical University Hospital, Taichung, Taiwan.
- 6 3D Printing Medical Research Institute, Asia University, Taichung, Taiwan.
- 7 Department of Neurosurgery, China Medical University Hsinchu Hospital, Hsinchu, Taiwan.
Item in Clipboard
Display options
Format
Abstract
Intraoperative navigation systems have been widely applied in spinal fusion surgery to improve the implantation accuracy of spinal screws using orthogonal tomographic and surface-rendering imaging. However, these images contain limited anatomical information and no information on bone volume contact by the implanted screw, which has been proven to affect the stability of implanted screws. This study proposed a novel drilled surface imaging technique that displays anatomical integration properties to calculate the contact bone volume (CBV) of the screws implanted along an implantation trajectory. A cylinder was used to represent the area traversed by the screws, which was manually rotated and translated to a predetermined implantation trajectory according to a vertebra model obtained using computed tomography (CT) image volumes. The drilled surface image was reconstructed by interpolating the CT numbers at the predefined sampling points on the cylinder surface. The anatomical integration property and CBV of the screw implanted along the transpedicular trajectory (TT) and cortical bone trajectory (CBT) were evaluated and compared. The drilled surface image fully revealed the contact anatomical structure of the screw under the trajectories, improving the understanding of the anatomical integration of the screw and surrounding tissues. On average, the CBV of the CBT was 30% greater than that of the TT. The proposed drilled surface image may be applied in preoperative planning and integrated into intraoperative navigation systems to evaluate the anatomical integration and degree of bone contact of the screw implanted along a trajectory.
Copyright: © 2023 Tang et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Conflict of interest statement
The authors have declared that no competing interests exist.
Figures
References
-
-
Steffee AD, Biscup RS, Sitkowski DJ. Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop Rel Res. 1986; 203: 45–53.
–
PubMed
-
-
-
Suk SI, Lee CK, Kim WJ, Chung YJ, Park YB, Song KY. Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Journal of the Korean Orthopaedic Association. 1995; 30(1): 49–58.
–
PubMed
-
MeSH terms
Grant support
Cite