Background:
Anterior cervical discectomy and fusion (ACDF) with a rigid interbody spacer is commonly used in the treatment of cervical degenerative disc disease. Although ACDF relieves clinical symptoms, it is associated with several complications such as pseudoarthrosis and adjacent segment degeneration. The concept of dynamic fusion has been proposed to enhance fusion and reduce implant subsidence rate and post-fusion stiffness; this pilot preclinical animal study was conducted to begin to compare rigid and dynamic fusion in ACDF.
Questions/purposes:
Using a pig model, we asked, is there (1) decreased subsidence, (2) reduced axial stiffness in compression, and (3) improved likelihood of bone growth with a dynamic interbody cage compared with a rigid interbody cage in ACDF?
Methods:
ACDF was performed at two levels, C3/4 and C5/6, in 10 pigs weighing 48 to 55 kg at the age of 14 to 18 months (the pigs were skeletally mature). One level was implanted with a conventional rigid interbody cage, and the other level was implanted with a dynamic interbody cage. The conventional rigid interbody cage was implanted in the upper level in the first five pigs and in the lower level in the next five pigs. Both types of interbody cages were implanted with artificial hydroxyapatite and tricalcium phosphate bone grafts. To assess subsidence, we took radiographs at 0, 7, and 14 weeks postoperatively. Subsidence less than 10% of the disc height was considered as no radiologic abnormality. The animals were euthanized at 14 weeks, and each operated-on motion segment was harvested. Five specimens from each group were biomechanically tested under axial compression loading to determine stiffness. The other five specimens from each group were used for microCT evaluation of bone ingrowth and ongrowth and histologic investigation of bone formation. Sample size was determined based on 80% power and an α of 0.05 to detect a between-group difference of successful bone formation of 15%.
Results:
With the numbers available, there was no difference in subsidence between the two groups. Seven of 10 operated-on levels with rigid cages had subsidence on a follow-up radiograph at 14 weeks, and subsidence occurred in two of 10 operated-on levels with dynamic cages (Fisher exact test; p = 0.07). The stiffness of the unimplanted rigid interbody cages was higher than the unimplanted dynamic interbody cages. After harvesting, the median (range) stiffness of the motion segments fused with dynamic interbody cages (531 N/mm [372 to 802]) was less than that of motion segments fused with rigid interbody cages (1042 N/mm [905 to 1249]; p = 0.002). Via microCT, we observed bone trabecular formation in both groups. The median (range) proportions of specimens showing bone ongrowth (88% [85% to 92%]) and bone volume fraction (87% [72% to 100%]) were higher in the dynamic interbody cage group than bone ongrowth (79% [71% to 81%]; p < 0.001) and bone volume fraction (66% [51% to 78%]; p < 0.001) in the rigid interbody cage group. The percentage of the cage with bone ingrowth was higher in the dynamic interbody cage group (74% [64% to 90%]) than in the rigid interbody cage group (56% [32% to 63%]; p < 0.001), and the residual bone graft percentage was lower (6% [5% to 8%] versus 13% [10% to 20%]; p < 0.001). In the dynamic interbody cage group, more bone formation was qualitatively observed inside the cages than in the rigid interbody cage group, with a smaller area of fibrotic tissue under histologic investigation.
Conclusion:
The dynamic interbody cage provided satisfactory stabilization and percentage of bone ongrowth in this in vivo model of ACDF in pigs, with lower stiffness after bone ongrowth and no difference in subsidence.
Clinical relevance:
The dynamic interbody cage appears to be worthy of further investigation. An animal study with larger numbers, with longer observation time, with multilevel surgery, and perhaps in the lumbar spine should be considered.