Complications associated with single-position prone lateral lumbar interbody fusion: a systematic review and pooled analysis


Objective:

Lateral lumbar interbody fusion (LLIF) is a workhorse surgical approach for lumbar arthrodesis. There is growing interest in techniques for performing single-position surgery in which LLIF and pedicle screw fixation are performed with the patient in the prone position. Most studies of prone LLIF are of poor quality and without long-term follow-up; therefore, the complication profile related to this novel approach is not well known. The objective of this study was to perform a systematic review and pooled analysis to understand the safety profile of prone LLIF.


Methods:

A systematic review of the literature and a pooled analysis were conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. All studies reporting prone LLIF were assessed for inclusion. Studies not reporting complication rates were excluded.


Results:

Ten studies meeting the inclusion criteria were analyzed. Overall, 286 patients were treated with prone LLIF across these studies, and a mean (SD) of 1.3 (0.2) levels per patient were treated. The 18 intraoperative complications reported included cage subsidence (3.8% [3/78]), anterior longitudinal ligament rupture (2.3% [5/215]), cage repositioning (2.1% [2/95]), segmental artery injury (2.0% [5/244]), aborted prone interbody placement (0.8% [2/244]), and durotomy (0.6% [1/156]). No major vascular or peritoneal injuries were reported. Sixty-eight postoperative complications occurred, including hip flexor weakness (17.8% [21/118]), thigh and groin sensory symptoms (13.3% [31/233]), revision surgery (3.8% [3/78]), wound infection (1.9% [3/156]), psoas hematoma (1.3% [2/156]), and motor neural injury (1.2% [2/166]).


Conclusions:

Single-position LLIF in the prone position appears to be a safe surgical approach with a low complication profile. Longer-term follow-up and prospective studies are needed to better characterize the long-term complication rates related to this approach.


Keywords:

LLIF; XLIF; complications; extreme lateral interbody fusion; lateral lumbar interbody fusion; prone transpsoas; single-position surgery.