Objective:
Study perioperative strategies for optimizing neuroprotection in complex spine deformity correction surgery.
Methods:
We report the case of a patient with severe lumbar dextroscoliosis, thoracolumbar junction hyperkyphosis with a 40-degree Cobb angle levoconvex scoliosis who underwent spinal deformity correction with loss of neuromonitoring during surgery. We performed a literature review on perioperative management of complex spine deformity.
Results:
A 50-year-old man presented with lumbar pain and right L4 radiculopathy. Surgical intervention for deformity correction and decompression was indicated with T4-L4 posterior instrumentation L2/L3 and L3/L4 transforaminal lumbar interbody fusion. Surgery was aborted due to the loss of neuromonitoring. Postsurgery, the patient had left sensory deficit and the neurocritical care team clinically suspected and deduced the anatomic location of the spinal cord compression. Magnetic resonance imaging confirmed a T10-T11 hyperintensity suggestive of cord ischemia due to osteophyte compressing the spinal cord. The patient underwent a second corrective surgery with no intraoperative events and has no long-term neurological sequela.
Conclusions:
This case illustrates that a comprehensive perioperative approach and individualized risk factor assessment is useful in complex spine deformity surgery. Further research is needed to determine how this individualized comprehensive approach can lead to intraoperative and postoperative countermeasures that improved spine surgery outcomes.
Level of evidence:
Level V.