OBJECTIVE:
The objective of this study was to describe and evaluate a new surgical procedure for the correction of coronal imbalance (CI) in adult spinal deformity patients, called the “kickstand rod” technique.
METHODS:
The authors analyzed the records of 24 consecutive patients with pediatric and adult spinal deformity and CI treated between July 2015 and October 2017 with a long-segment fusion and a kickstand rod. For the kickstand rod technique, an iliac screw was placed on the ipsilateral side of the trunk shift and connected proximally through a side-by-side domino link to the thoracolumbar junction; this rod was distracted to promote coronal plane balancing. Distraction occurred with the rod on the contralateral side locked in order to preserve sagittal correction. Radiographic and clinical analyses were conducted to evaluate the outcomes and possible complications of the kickstand rod technique.
RESULTS:
The mean age of the patients was 55 years (range 14-73 years). Eighteen of the 24 patients were female. CI preoperatively was a mean of 63 mm, and the mean measurement at the final follow-up (mean duration 1.4 years) was 47 mm. There were no neurological, vascular, or implant-related complications in any of the patients. One patient developed wound dehiscence that was successfully treated without implant removal, and one developed proximal junctional kyphosis requiring extension of the construct proximally. One patient also returned to the operating room for excision of a spinous process. There were no complaints about screw prominence, kickstand construct failure, or significant worsening of CI after surgery.
CONCLUSIONS:
The kickstand rod technique is safe and effective for the correction of CI in spinal deformity patients. This technique was found to provide marked coronal correction and additional strength to the overall construct without significant adverse consequences.