Background:
Ureteral injury during lateral lumbar interbody fusion (LLIF) is uncommon. However, it is a serious complication that may require additional surgery should it occur. The objective of this study was to evaluate whether there was any change in the position of the left ureter between preoperative biphasic contrast-enhanced CT scanned in the supine position and intraoperative scanning in the right lateral decubitus position after stent placement, to assess the risk of ureteral injury in the actual surgical position.
Methods:
The position of the left ureter scanned with the O-arm navigation system with the patient in the right lateral decubitus position and its position on preoperative biphasic contrast-enhanced CT images scanned with the patient in the supine position were investigated comparing their positions at the L2/3, L3/4, and L4/5 levels.
Results:
The ureter was located along the interbody cage insertion trajectory in 25 of 44 disc levels (56.8%) in the supine position, but in only 4 (9.5%) in the lateral decubitus position. The proportion of patients in whom the left ureter was located lateral to the vertebral body (along the LLIF cage insertion trajectory) at each level was 80% in the supine position and 15.4% in the lateral decubitus position at the L2/3 level, 53.3% in the supine position and 6.7% in the lateral decubitus position at the L3/4 level, and 33.3% in the supine position and 6.7% in the lateral decubitus position at the L4/5 level.
Conclusion:
The proportion of patients in whom the left ureter was located on the lateral surface of the vertebral body when the patient was in the actual surgical position (lateral decubitus position) was 15.4% at the L2/3 level, 6.7% at the L3/4 level, and 6.7% at the L4/5 level, suggesting that caution is required during LLIF surgery.
Keywords:
Complications; Lateral lumbar interbody fusion (LLIF); Position of the left ureter; Ureteral injury.