doi: 10.3390/medicina59020372.
1
2
, Hiroaki Nakashima
1
, Ryuichi Shinjo
2
, Yujiro Kagami
2
, Masaaki Machino
1
, Sadayuki Ito
1
, Jun Ouchida
1
, Kazuaki Morishita
1
, Ryotaro Oishi
1
, Ippei Yamauchi
1
, Shiro Imagama
1
Affiliations
Affiliations
- 1 Department of Orthopedic Surgery, Graduate School of Medicine, Nagoya University, 65 Tsurumai, Showa-ku, Nagoya 466-8560, Japan.
- 2 Department of Orthopedic Surgery, Anjo Kosei Hospital, 28 Higashihirokute, Anjo 446-8602, Japan.
Item in Clipboard
Naoki Segi et al.
Medicina (Kaunas).
.
Display options
Format
doi: 10.3390/medicina59020372.
Authors
1
2
, Hiroaki Nakashima
1
, Ryuichi Shinjo
2
, Yujiro Kagami
2
, Masaaki Machino
1
, Sadayuki Ito
1
, Jun Ouchida
1
, Kazuaki Morishita
1
, Ryotaro Oishi
1
, Ippei Yamauchi
1
, Shiro Imagama
1
Affiliations
- 1 Department of Orthopedic Surgery, Graduate School of Medicine, Nagoya University, 65 Tsurumai, Showa-ku, Nagoya 466-8560, Japan.
- 2 Department of Orthopedic Surgery, Anjo Kosei Hospital, 28 Higashihirokute, Anjo 446-8602, Japan.
Item in Clipboard
Display options
Format
Abstract
Background and Objectives: To prevent postoperative problems in extreme lateral interbody fusion (XLIF), it is critical that the vertebral endplate not be injured. Unintentional endplate injuries may depend on the cage. A novel porous titanium cage for XLIF has improved geometry with a tapered tip and smooth surface. We hypothesized that this new cage should lead to fewer endplate injuries. Materials and Methods: This retrospective study included 32 patients (mean 74.1 ± 6.7 years, 22 females) who underwent anterior and posterior combined surgery with XLIF for lumbar degenerative disease or adult spinal deformity from January 2018 to June 2022. A tapered 3D porous titanium cage (3DTi; 11 patients) and a squared PEEK cage (sPEEK; 21 patients) were used. Spinal alignment values were measured on X-ray images. Vertebral endplate concavity (VEC) was defined as concavity ≥ 1 mm of the endplate on computed tomography (CT) images, which were evaluated preoperatively and at 1 week and 3 months postoperatively. Results: There were no significant differences in the patient demographic data and preoperative and 3-month postoperative spinal alignments between the groups. A 3DTi was used for 25 levels and an sPEEK was used for 38 levels. Preoperative local lordotic angles were 4.3° for 3DTi vs. 4.7° for sPEEK (p = 0.90), which were corrected to 12.3° and 9.1° (p = 0.029), respectively. At 3 months postoperatively, the angles were 11.6° for 3DTi and 8.2° for sPEEK (p = 0.013). VEC was present in 2 levels (8.0%) for 3DTi vs. 17 levels (45%) for sPEEK (p = 0.002). After 3 months postoperatively, none of the 3DTi had VEC progression; however, eight (21%) levels in sPEEK showed VEC progression (p = 0.019). Conclusions: The novel 3DTi cage reduced endplate injuries by reducing the endplate load during cage insertion.
Keywords:
cage subsidence; extreme lateral interbody fusion; lateral lumber interbody fusion; poly-ether-ether-ketone; three-dimensional porous titanium; vertebral endplate injury.
Conflict of interest statement
The authors declare no conflict of interest.
Figures
Similar articles
-
PEEK versus titanium cages in lateral lumbar interbody fusion: a comparative analysis of subsidence.
Campbell PG, Cavanaugh DA, Nunley P, Utter PA, Kerr E, Wadhwa R, Stone M.
Campbell PG, et al.
Neurosurg Focus. 2020 Sep;49(3):E10. doi: 10.3171/2020.6.FOCUS20367.
Neurosurg Focus. 2020.PMID: 32871573
-
Assessment and classification of subsidence after lateral interbody fusion using serial computed tomography.
Malham GM, Parker RM, Blecher CM, Seex KA.
Malham GM, et al.
J Neurosurg Spine. 2015 Nov;23(5):589-597. doi: 10.3171/2015.1.SPINE14566. Epub 2015 Jul 24.
J Neurosurg Spine. 2015.PMID: 26207320
-
Poor Bone Quality, Multilevel Surgery, and Narrow and Tall Cages Are Associated with Intraoperative Endplate Injuries and Late-onset Cage Subsidence in Lateral Lumbar Interbody Fusion: A Systematic Review.
Wu H, Shan Z, Zhao F, Cheung JPY.
Wu H, et al.
Clin Orthop Relat Res. 2022 Jan 1;480(1):163-188. doi: 10.1097/CORR.0000000000001915.
Clin Orthop Relat Res. 2022.PMID: 34324459
Free PMC article. -
[Application of three-dimensional printed porous titanium alloy cage and poly-ether-ether-ketone cage in posterior lumbar interbody fusion].
Wang Y, Zhou Y, Chai X, Zhuo H.
Wang Y, et al.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2022 Sep 15;36(9):1126-1131. doi: 10.7507/1002-1892.202204011.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2022.PMID: 36111476
Free PMC article.Clinical Trial.
Chinese. -
Influence of the geometric and material properties of lumbar endplate on lumbar interbody fusion failure: a systematic review.
Yu Y, Robinson DL, Ackland DC, Yang Y, Lee PVS.
Yu Y, et al.
J Orthop Surg Res. 2022 Apr 10;17(1):224. doi: 10.1186/s13018-022-03091-8.
J Orthop Surg Res. 2022.PMID: 35399075
Free PMC article.Review.
References
-
-
Wu H., Shan Z., Zhao F., Cheung J.P.Y. Poor Bone Quality, Multilevel Surgery, and Narrow and Tall Cages Are Associated with Intraoperative Endplate Injuries and Late-onset Cage Subsidence in Lateral Lumbar Interbody Fusion: A Systematic Review. Clin. Orthop. Relat. Res. 2022;480:163–188. doi: 10.1097/CORR.0000000000001915.
–
DOI
–
PMC
–
PubMed
-
Grant support
This research received no external funding.